Project

General

Profile

TR-702 The level and audio loudness meter

Description

Page with description: Description_TP-702

Update software and firmware TR-702

It is necessary to install the latest version of the software and firmware on the TR-702-1 and TR-702-2.
Installing the latest software version or firmware on only one unit will result in incorrect operation. For example, units will not be able to establish a connection with each other.

 

Firmware Update TR-702-1

To upgrade the firmware you need:

  • computer running Windows 7 or newer;
  • USB cable type A - type B;
  • firmware file firmware.bin (version 1.3)

To update, do the following:

  • disconnect the power cable from the TR-702-1;
  • connect USB cable type A - type B computer and TR-702-1;
  • hold the button next to the USB connector on the TR-702-1 unit;
  • connect the power cable to the TR-702-1;
  • release the button next to the USB connector on the TR-702-1 unit;
  • find and open the appeared disk with the name TR-702 in the explorer;
  • replace the existing firmware.bin firmware file with a new one;
  • disconnect the power cable from the TR-702-1;
  • connect the power cable to the TR-702-1

Software Update TR-702-2

To upgrade the TP-702-2 software, you need a USB drive with an update file.
The current software version of the TP-702-2 is displayed in Menu-System-Settings-Version.
The file has the format name update_xxx.ebm, where the characters between the underscore and the dot are the version number.

To update, do the following:

  • prepare a normal FAT32 USB drive with the update in the root (file update_xxx.ebm);
  • insert the USB drive into the USB connector of the device and apply power;
  • wait for the download of the loudness meter application (appearance of the main graphic screen of the meter);
  • open Menu-System-Settings-Version and make sure that the new version of the application is displayed;
  • if necessary, enter the IP address of the input module;
  • turn off the device through Menu-System-Settings;
  • after shutdown, remove the USB.

7.PNG


Add picture from clipboard (Maximum size: 742 MB)